0x13 updating the face match dating site

KEYWORDS: 1797-Slot X Drive Array – Write-Back Cache Backup Previously Failed; 1793-Slot X Drive Array – Data in Cache has been lost; 1719-Slot x Drive Array – A controller failure event occurred prior to this power-up; 1719-Slot x Drive Array – A controller failure event occurred prior to this power-up.(Previous lock up code = 0x13) Hardware Platforms Affected: HP Pro Liant BL460c Gen8 Server Blade, HP Pro Liant DL160 Gen8 Server, HP Pro Liant DL320e Gen8 v2 Server, HP Pro Liant DL360e Gen8 Server, HP Pro Liant DL360p Gen8 SE Server, HP Pro Liant DL380e Gen8 Server, HP Pro Liant DL380p Gen8 Server, HP Pro Liant DL385p Gen8 Server, HP Pro Liant DL560 Gen8 Server, HP Pro Liant DL580 Gen8 Server, HP Pro Liant ML350e Gen8 v2 Server, HP Pro Liant ML350p Gen8 Server, HP Pro Liant SL210t Gen8 Server, HP Pro Liant SL270s Gen8 SE Server, HPE Pro Liant DL580 Gen9 Server Hewlett Packard Enterprise Company shall not be liable for technical or editorial errors or omissions contained herein.The information in this document is subject to change without notice.Hewlett Packard Enterprise Company and the names of Hewlett Packard Enterprise Company products referenced herein are trademarks of Hewlett Packard Enterprise Company in the United States and other countries.Advisory: HPE Smart Array Controllers - CUSTOMER ACTION REQUIRED: Update to Firmware Version 3.54 to Correct Intermittent Controller Lockup Issues on Certain Pro Liant Gen8 Server Platforms and on the Pro Liant DL580 Gen9 Server On certain HPE Pro Liant Gen8 Servers or on a Pro Liant DL580 Gen9 server configured with a Smart Array Px3x controller running firmware version 3.02 (or earlier), the following controller lockup (POST error code) may appear due to timing errors (also known as 'race conditions'): These "race conditions" were introduced when the controller firmware advanced its codebase to use multiple CPU cores in the Gen8 and Gen9 RAID ASIC.The use of multiple CPU cores resulted in a significant performance increase over the single core architecture present in all previous versions of Smart Array controller firmware.Non-Maskable Interrupt (NMI) might occur on systems with a Windows OS and HPE Gen9 Smart Array or Smart HBA adapters and performing continuous reboot testing.

Multiple direct attach SATA drives within a cluster might show the same World Wide Name (WWN) when using Microsoft Storage Spaces Direct (S2D).NAVIGATION TIP : For hints on navigating to locate the latest drivers, patches, and other support software downloads for Pro Liant servers and Options, refer to the Navigation Tips document .SEARCH TIP : For hints on locating similar documents on HPE.com, refer to the Search Tips document .HPE Smart Array Firmware Version 3.54 corrects the following key issues: To resolve the issues presented in the Smart Array version 3.02 (or earlier), HPE strongly recommends upgrading to the Smart Array Controller Firmware Version 3.54 (or later).To download and install the Smart Array Px3x Controller Firmware version 3.54 (or later) on the Pro Liant server, select a download link below depending on the operating system installed: For further assistance, contact the HPE Support Center: In North America, contact HPE Customer Support at 1-844-806-3425.

Leave a Reply